Thermal and Sound Insulation > Floor Insulation > Under Screed Isolation Solutions























Under Screed Insolation Solutions
You want to use such a product in your construction so that it provides both sound and heat insulation, does not collapse and is long-lasting. Here, we have collected the features you should look for about the product you will ask from the companies for this.
Features to look for in a screed underlayment
-Thermal conductivity value must be low
-Impact sound value must be high
-Under alum product must breathe
-Should not produce insects and pests
-Less load on the building
-It must not be crushed. It should serve for the life of the building.
-It must have all documents and tests including TSE, UTO (ITBAK)!
Videos :


Under Screed Thermal Insolation Solutions
You want to use such a product in your construction so that it provides both sound and heat insulation, does not collapse and is long-lasting. Here, we have collected the features you should look for about the product you will ask from the companies for this.

Advantages of Screed Underlayment
-The slurry of the alum does not enter its structure. Therefore, nylon etc. products are not used.
-Provides high heat insulation.
-It prevents impact-induced sounds from going to the lower floor.
-Breathes. It does not cause moisture, dampness and mold on the lower floor ceiling.
-Does not give waste.
-Easy to apply.
-It can be worked on comfortably. Does not break and deform.
-It is healthy.
-Additional wall tape is not used for floating flooring.


Under Screed Sound Insolation Solutions
You want to use such a product in your construction so that it provides both sound and heat insulation, does not collapse and is long-lasting. Here, we have collected the features you should look for about the product you will ask from the companies for this.

Advantages of Screed Underlayment
-The slurry of the alum does not enter its structure. Therefore, nylon etc. products are not used.
-Provides high heat insulation.
-It prevents impact-induced sounds from going to the lower floor.
-Breathes. It does not cause moisture, dampness and mold on the lower floor ceiling.
-Does not give waste.
-Easy to apply.
-It can be worked on comfortably. Does not break and deform.
-It is healthy.
-Additional wall tape is not used for floating flooring.
Under-screed aging test after 10 years: 2.86% loss.
Thermal conductivity value: λ 0,0331.
Impact sound insulation test: ΔLw 29 dB.
Fire Reaction Class: B-s1,d0
Water Vapor Permeability: 4,2
Apparent Density Determination (kg/m3): 67,1
Thickness Class: T1
*The above mentioned values are valid for izoBOZZ FeltBi 15mm product.
Product Code | Thickness | Weight | Impact Sound Insulation | Size |
FZ-05 | 5mm | 500 g/m² | 19 dB | 1m x 40m |
FZ-07 | 7mm | 700 g/m² | 27 dB | 1m x 20m |
FZ-10 | 10mm | 1000 g/m² | 27 dB | 1m x 15m |
FZ-15 | 15mm | 1000 g/m² | 29 dB | 1m x 15m |
FZ-20 | 20mm | 1500 g/m² | 29 dB | 1m x 3m x 4 use |
* Ürünler hakkında detaylı bilgi için ürün kodlarına tıklayabilirsiniz.
- Itbak UTO 2023/142 (National Technical Approval-NTA)
- Itbak UTO 2023/143 (National Technical Approval-NTA)
- izoBOZZ TSE Certificate
- FeltBi TSE Certificate
- CE Certificate
- REACH
- RoHS
- Thermal Conductivity W Div MK- TS EN 12667
- Fire Reaction Class – TS EN 13823-2010
- 10% plaster mesh sound insulation on a single wall
- Sound insulation with glued gypsum board without construction on a single wall of 10
- 5-7mm Under Alum Test – TS EN ISO 10140-1:2021
- 15mm Under Screed Impact Test TS EN ISO 10140-3
- 5-7 mm Under Pressure Creep Determination TS EN 1606- 2013-06
- Determination of Creep Under 15mm Pressure TS EN 1606- 2013-06
- TS EN 12086 12087 12088 WATER VAPOR PERMEABILITY TEST
- 3-4 mm Under Parquet Impact Test
- 4-5 mm Under Parquet Impact Test
- 5-7mm Under Parquet Impact Test
- 9-10mm Under Parquet Impact Test
The surface is cleaned first.
Surface defects do not prevent the laying of izoBOZZ FeltBi felt.
IzoBOZZ FeltBi felt is laid side by side so that there is no gap on the floor.
There is no need to tape the joints.
Impact sounds travel to the lower floors both directly and through the side walls. For this reason, isoBOZZ FeltBi felts are turned to the wall as much as the thickness of the screed to be laid to cut the wall sound connection.
No additional tape is required.
The screed is poured so that it does not exceed the felt level.
When pouring the screed, since the grout of the screed does not penetrate into the structure of isoBOZZ FeltBi (see TSE Impact test), there is no need to lay nylon etc. on it.
Excess felts remaining above the screed level are cleaned by cutting with the help of a cutter after the parquet is laid.