Thermal and sound Insulation Solutıons
Underfloor Heating Systems Sound Insulation Solutions
"Floor heating systems are generally used to provide thermal insulation; they are inadequate in sound insulation. The materials used are styrofoam. Styrofoam is not a sound insulation material. However, when laid under floor heating systems, our IzoBOZZ FeltBi Felts not only reduce heat loss but also provide an effective solution for impact sound insulation." It provides a quieter and more comfortable environment by preventing the spread of sounds that may travel downstairs. If you do not want to embark on an irreversible adventure, we definitely recommend using izoBOZZ Feltbi felts under the floor heating system. We try to reduce these sounds by applying reverse ceiling felts when not in use. It does not give results. The correct application is to use our felt products under the underfloor heating system.
Advantages
-It prevents impact-related sounds from traveling downstairs.
-He breathes. It does not cause moisture.
-It does not cause inflammation.
-It is easy to apply.
-It can be worked on easily. It does not break or deform.
-It is healthy.
-Wall tape is not used for floating flooring.
Application Videos :
-Under-screed aging test after 10 years: 2.86% loss.
-Thermal conductivity value: λ 0.0331.
-Impact sound insulation test: ΔLw 29 dB.
-Fire Reaction Class: B-s1,d0
-Water Vapor Permeability: 4.2
-Apparent Density Determination (kg/m3): 67.1
-Thickness Class: T1
*The values stated above are valid for the izoBOZZ FeltBi 15mm product.
Code | Thickness | Wight | Dimensions | Packing |
FZ-03 | 3mm | 350 g/m² | 1m x 50m | Rulo |
FZ-05 | 5mm | 500 g/m² | 1m x 40m | Rulo |
FZ-07 | 7mm | 700 g/m² | 1m x 20m | Rulo |
FZ-10 | 10mm | 1000 g/m² | 1m x 15m | Rulo |
FZ-15 | 15mm | 1000 g/m² | 1m x 15m | Rulo |
* For the products Technical Specifications (TDS) please click the Code of Products.
- İtbak UTO 2023/142
- İtbak UTO 2023/143
- izoBOZZ TSE Certificate
- FeltBi TSE Certificate
- REACH
- RoHS
- Yangın Tepki Sınıfı – TS EN 13823-2010
- 5-7mm Şap Altı Testi – TS EN ISO 10140-1:2021
- 15mm Şap Altı Darbe Testi TS EN İSO 10140-3
- 5-7 mm Basınç Altı Sünme Tayini TS EN 1606- 2013-06
- 15mm Basınç Altında Sünme Tayini TS EN 1606- 2013-06
Uygulama 1
- Önce yüzey temizliği yapılır.
- Yüzeydeki bozukluklar izoBOZZ FeltBi keçenin serilmesine engel değildir.
- İzoBOZZ FeltBi keçe zemine boşluk kalmayacak şekilde yan yana serilir.
- Ek yerlerinden bantlamaya gerek yoktur.
- Darbe sesleri alt katlara hem doğrudan hem de yan duvarlardan çarparak ilerler. Bu nedenle duvar ses bağlantısını kesmek için atılacak şap kalınlığı kadar izoBOZZ FeltBi keçeler duvara döndürülür.
- Ek banta gerek yoktur.
- Yerden ısıtma kılçıkları gerekli şekilde keçe üzerine sabitlenir.
- Şap, keçe seviyesini geçmeyecek şekilde dökülür.
Uygulama 2
- Önce yüzey temizliği yapılır.
- Yüzeydeki bozukluklar izoBOZZ FeltBi keçenin serilmesine engel değildir.
- İzoBOZZ FeltBi keçe zemine boşluk kalmayacak şekilde yan yana serilir.
- Ek yerlerinden bantlamaya gerek yoktur.
- Darbe sesleri alt katlara hem doğrudan hem de yan duvarlardan çarparak ilerler. Bu nedenle duvar ses bağlantısını kesmek için atılacak şap kalınlığı kadar izoBOZZ FeltBi keçeler duvara döndürülür.
- Ek banta gerek yoktur.
- Şap, keçe seviyesini geçmeyecek şekilde dökülür.